Research Chemical ,Steriods Powder,Loss Weight Cosmetic Peptides Co., Ltd. , http://www.ns-pharmaceuticals.com
Medical Diagnosis of Galactophore X-ray Machine (High-frequency)
X-ray Generator
Generator Type: High Frequency Inverter 40kHz
Input Power: Single phase 220VAC, 50/60Hz
Radiographic Ratings: Large Focal Point 20-35KV/1-300mAs
Small Focal Point 20-35KV/1-100mAs
Power Rating: 1.2kW
X-ray Tube
Model: Fixed anode, China Hang Zhou XD7(X791)
Focal Spot Size: Dual Focus 0.5mm
Target Material: Molybdenum (Mo)
Port Material: Beryllium (Be)
Anode Heat Storage: 63KHU
Anode Cooling: Air cooling
Filtration: Mo(0.03mm), Al(0.5mm)
Radiographic Stand
C-ARM: Vertical Movement: 60cm (70~130cm) Motorized
Rotations Deg: ± 180° Motorized (Deg. Data Display)
SID: 65cm
Cassette Image Receptor
18× 24cm
Line Voltage
220Vac@15A, Single phase
Weight 200kg
Bucky: (Optional)
Bucky Device: 18× 24cm Bucky drive mechanism
Grid Ratio: 3.5: 1, 30 Line/cm
Comfortable Compression(Optional):
When some degree of pressure is required for radiography, it allows you to presser the appropriate pressure(up to a maximum of 20kg)and is equipped with MICOM Control's Soft-touch system which is designed to minimize the discomfort of the examine with in the pressure range.
Tissue Compression: Manual and Motorized (Max 20kg)
Compression Force and Thickness Data Display
Micom Control's Compression
Automatic Release
Intelligent Automatic Exposure Control (AEC) (Optional)
With the Automatic Exposure Control system, it is possible to produce images with reliable intensity suitable for and film, screen, or method of radiography.
Furthermore, this diagonosis X-ray machine greatly enhances the convenience of radiography by embedding the Full-AEC function which is capable of utilizing the Auto kV.
Type: Solid-State Detector or PMT Detector
Microprocessor Control
AEC Mode: Full AEC(Auto kV)
Semi AEC (KV Select)
Manual (kV, mAs Select)
Density Adjustment: 10 density steps.
 Model
 Fixed anode, X-ray tube made by joint venture
 Focal Spot Size
 Double Focus 0.2mm/0.4mm
 Target Material
 Molybdenum (Mo)
 Port Material
 Beryllium (Be)
 Anode Heat Capacity
 63KHU
 Anode Cooling
 Air cooling
 Filtration
 Mo(0.03mm),Al(0.5mm)
High-frequency Mammography X-ray Machine YSX980D
Medical Diagnosis of Galactophore X-ray Machine (High-frequency)
X-ray Generator
Generator Type: High Frequency Inverter 40kHz
Input Power: Single phase 220VAC, 50/60Hz
Radiographic Ratings: Large Focal Point 20-35KV/1-300mAs
Small Focal Point 20-35KV/1-100mAs
Power Rating: 1.2kW
X-ray Tube
Model: Fixed anode, China Hang Zhou XD7(X791)
Focal Spot Size: Dual Focus 0.5mm
Target Material: Molybdenum (Mo)
Port Material: Beryllium (Be)
Anode Heat Storage: 63KHU
Anode Cooling: Air cooling
Filtration: Mo(0.03mm), Al(0.5mm)
Radiographic Stand
C-ARM: Vertical Movement: 60cm (70~130cm) Motorized
Rotations Deg: ± 180° Motorized (Deg. Data Display)
SID: 65cm
Cassette Image Receptor
18× 24cm
Line Voltage
220Vac@15A, Single phase
Weight 200kg
Bucky: (Optional)
Bucky Device: 18× 24cm Bucky drive mechanism
Grid Ratio: 3.5: 1, 30 Line/cm
Comfortable Compression(Optional):
When some degree of pressure is required for radiography, it allows you to presser the appropriate pressure(up to a maximum of 20kg)and is equipped with MICOM Control's Soft-touch system which is designed to minimize the discomfort of the examine with in the pressure range.
Tissue Compression: Manual and Motorized (Max 20kg)
Compression Force and Thickness Data Display
Micom Control's Compression
Automatic Release
Intelligent Automatic Exposure Control (AEC) (Optional)
With the Automatic Exposure Control system, it is possible to produce images with reliable intensity suitable for and film, screen, or method of radiography.
Furthermore, this diagonosis X-ray machine greatly enhances the convenience of radiography by embedding the Full-AEC function which is capable of utilizing the Auto kV.
Type: Solid-State Detector or PMT Detector
Microprocessor Control
AEC Mode: Full AEC(Auto kV)
Semi AEC (KV Select)
Manual (kV, mAs Select)
Density Adjustment: 10 density steps.
 Model
 Fixed anode, X-ray tube made by joint venture
 Focal Spot Size
 Double Focus 0.2mm/0.4mm
 Target Material
 Molybdenum (Mo)
 Port Material
 Beryllium (Be)
 Anode Heat Capacity
 63KHU
 Anode Cooling
 Air cooling
 Filtration
 Mo(0.03mm),Al(0.5mm)
YSX980D Medical Hospital High Frequency X Ray Mammography Equipment
Model NO.: YSX980D
Radiographic Ratings: Large Focal Point 20-35kv/1-300mas
Small Focal Point: 20-35kv/1-100mas
Power Rating: 1.2kw
Trademark: YSENMED
Transport Package: Wooden Box
Specification: ISO certificate
Origin: China
HS Code: 9022199090
Model NO.: YSX980D
Radiographic Ratings: Large Focal Point 20-35kv/1-300mas
Small Focal Point: 20-35kv/1-100mas
Power Rating: 1.2kw
Trademark: YSENMED
Transport Package: Wooden Box
Specification: ISO certificate
Origin: China
HS Code: 9022199090
High-frequency Mammography X-ray Machine YSX980D