Item No: Â Â Â Â Â Â BW2B Features:
Product Name: Vital signs monitor
This tabletop vital signs monitor, coming with standard parameter: SPO2, NIBP (non-invasive blood pressure), 2-temperature, Pulse Rate, with  reusable spo2 sensor, a good choice for clinics, hospitals and home use.
*Bright, Easy-to-Read Large LED Display
*Durable, Compact and Lightweight
*Long-life Internal Rechargeable Battery for Uninterrupted Monitoring
*Accurate and Reliable During Low Perfusion and Montion
*Audible/Visual Three Level Alarms with Alarm Volume Control
*72-hour Data Memory Allowing On-screen Data Replay
*Suitable for Adult, Pediatric and Neonate
*Optional Built-in Thermal Recorder
*Standard RS232 Port for External Printer and Central Monitoring
Â
Technical Specifications
* SpO2 Accuracy
No Motion:
Adults, Pediatrics: 70~100%  ±2%
         0~69% unspecified
Neonates:     70~100%  ±3%
         0~69% unspecified
With Motion:
Adults, Pediatrics: 70~100%  ±3%
         0~69% unspecified
Neonates:     70~100% ±4%
         0~69% unspecified
Low Perfusion:
Adults, Pediatrics: 70~100%  ±3%
        0~69% unspecified
Neonates:    70~100%  ±4%
        0~69% unspecified
Â
*Pulse Rate Accuracy
No Motion:
Adults, Pediatrics, Neonates:  ±3%
With Motion:
Adults, Pediatrics, Neonates:  ±5%
Low Perfusion:
Adults, Pediatrics, Neonates:  ±5%
Â
*Non-Invasive Blood Pressure (NIBP)
Measurement type:
Adult, Pediatric, Neonatal
Â
Measurement range
Adult:
Systolic   40bpm~270mmHg
Diastolic  20bpm~200mmHg
Mean    30bpm~220mmHg
Pediatric:
Systolic   40bpm~180mmHg
Diastolic  15bpm~160mmHg
Mean    20bpm~170mmHg
Neonatal:
Systolic   30bpm~140mmHg
Diastolic  15bpm~100mmHg
Mean    20bpm~115mmHg
Â
Accuracy: +-3mmHg or 2% (choice max)
Resolution: 1mmHg
Protection: over pressure
Â
*Performance Measurement Range
SpO2: 0 to 100%
Pulse Rate: 30bpm ~ 250bpm
Â
*Alarm
Audible/Visual Alarms
Adjustable Alarm Limits
Â
*2-Temperature
Measurement range: 25 to 45 Celsius degree
Accuracy: +- 0.2 Celsius degree
Â
*Output
RS-232 Serial Port for Digital Output
Nurse Call Function
Â
*Power Requirements:
100~240VAC, 50/60Hz, 20VA
Fuse Rating: 1.0A
Â
*Battery
Internal Battery: 12V
Battery Capacity: up to 24 hours
Â
*Environment
Opreation Temperature: 5 to 40 Celsius degree (41 to 104 Fahrenheit Degree )
Humidity: 10 ~ 95%
Transport/Storage Temperature:
-20 to +70 Celsius degree  (-4 to 158 Fahrenheit Degree)
Humidity: 10 to 95%
Â
*Dimensions & Weight
264mm(W) x 95mm(H) x 172mm(D)
[10.39in(W) x 3.74in(H) x 6.77in(D)
Net Weight: 2.25kg/5ib
Â
*Compliance
EN60601-1/ GB9706.1
EN60601-1-2, EN60601-2-49
Â
Vital Signs Monitor, Patient Monitor, Patient Monitoring System, Medical Equipment, Bedside Patient Monitoring, ICU Device
Model NO.: BW2B
Trademark: BONDWAY
Specification: ISO13485 EN60601-1/ GB9706.1 EN60601-1-2, EN60601
Origin: CHINA
HS Code: 9018902000